Copper intersected in Stuart Shelf JV drilling
Released
Released
Announcement PDF
ASX: IVR
ASX ANNOUNCEMENT
16 July 2024
Sediment Hosted Copper Drilled in Stuart Shelf
Investigator Resources Limited (ASX: IVR, “Investigator” or the “Company”) is pleased to provide
details of drilling undertaken by Discover Co on Joint Venture tenements in the Stuart Shelf, South Australia.
Note: Details in this announcement relate to results provided by Discover Co and are appended in full. Readers are
directed to refer to the Competent Person declaration and accompanying Table 1 within Discover Co’s appended
document for detail.
Highlights:
8m @ 1.06% Cu from 62m in hole PE046 (as reported by Discover Co in their appended release)
Discover Co commit to $4M of expenditure over 4 years on transfer of Gold Road’s interests
Further drilling planned
Investigator’s Managing Director, Andrew McIlwain commented on Discover Co’s results:
“Discover Co had executed an agreement with Gold Road Resources to acquire their interest in
the Stuart Shelf which includes Gold Road’s 51% interest in some of Investigator’s tenements.
“In advance of the formal transfer of Gold Road’s interests, in May 2024 Discover Co undertook a
56-hole drill program for an approximate total of 4,400m, of which approximately 25% was drilled
on Investigator’s Joint Venture tenements.
“Hole PE046 located on Investigator’s Whittata tenement (EL6642) was reported by Discover Co as
returning the best intersection of the program.
“Discover Co are expediting plans to undertake further drilling to test the scale of this discovery.
“Discover Co’s primary focus in the Stuart Shelf is the discovery of Zambian Copper Belt style
sediment hosted copper under shallow cove, and is expected to spend $4 million over 4 years
within the Investigator Joint Venture tenements”.
Overview of the Joint Venture
In September 2020, Investigator’s subsidiary Gawler Resources Pty Ltd entered into a 3-Stage Earn-In
Joint Venture Agreement with then ASX listed DGO Gold.
In August 2022, Gold Road Resources Ltd (ASX:GOR) completed the takeover of DGO Gold, including its
subsidiary Yandan Gold Mines Pty Ltd, and the Stuart Shelf Earn-In to Joint Venture with Investigator.
At the end of September 2023, Gold Road had satisfied the Stage 1 Earn-In commitment of $2M and
accordingly a 51% interest in the tenements was transferred. These Joint Venture tenements are shown
in Figure 1 below.
Page | 1
ASX Release – Investigator
Sedimentary Copper Drilled Under Stuart Shelf Joint Venture
16 July 2024
Discover Co Pty Ltd, an unlisted entity led by former DGO Gold directors, has an agreement to acquire
Gold Road’s interests in the Stuart Shelf including their 51% interest in Investigator’s Pernatty Joint Venture tenements (EL6401, EL6640, EL6641, EL6642 and EL6643).
Figure 1: Investigator’s South Australian tenements
Investigator’s tenements, including those held in the Stuart Shelf Pernatty Joint Venture, can be seen
(shaded lighter grey) in Figure 1 above.
The tenements are situated in the highly prospective Olympic Domain, exploration will be advanced under
a re-cast 51:49 Joint Venture with Discover Co.
Investigator holds 100% ownership in the adjacent tenements that include Uneroo, Lake McFarlane and
Wartarka, totalling approximately 2,400km2.
Page | 2
ASX Release – Investigator
Sedimentary Copper Drilled Under Stuart Shelf Joint Venture
16 July 2024
The recent drilling executed by Discover Co Pty Ltd on licences held by Gawler Resources Pty Ltd (Gawler)
and Yandan Gold Mines Pty Ltd (Yandan) were completed pursuant to farm-in and joint venture terms
executed by Discover Co’s subsidiary Pernatty Co Pty Ltd (Pernatty).
Investigator (Gawler) have recast the earn-in terms with Discover Co (Pernatty - who has the right to Gold
Road’s 51%) such that Pernatty by spending $4m over a 4-year period on the Joint Venture tenements
can earn an additional 29% for a total equity interest of 80%.
Authorised by Andrew McIlwain, Managing Director.
For more information:
Andrew McIlwain
Peter Taylor
Managing Director
Media & Investor Relations
Investigator Resources Ltd
NWR Communications
+ 61 (0) 8 7325 2222
+ 61 (0) 412 036 231
amcilwain@investres.com.au
peter@nwrcommunications.com.au
About Investigator Resources
Investigator Resources Limited (ASX: IVR) is a metals explorer with a focus on the opportunities for silverlead, copper-gold and other metal discoveries. Investors are encouraged to stay up to date with Investigator’s news and announcements by registering their interest here: https://investres.com.au/enews-updates/
Capital Structure (as at 30 June 2024)
Directors & Management
Shares on issue
1,583,879,574
Dr Richard Hillis
Non-Exec. Chair
Listed Options
318,091,182
Mr Andrew McIlwain
Managing Director
Unlisted Options
28,500,000
Mr Andrew Shearer
Non-Exec. Director
Top 20 shareholders
29.6%
Ms Anita Addorisio
CFO & Company Secretary
Total number of shareholders
5,635
Total number of optionholders (IVRO)
1,254
Competent Person
The information in this announcement refers to exploration results compiled by Discover Co and their
consulting geologists and Investigator do not provide representation or support in relation to reporting
under the Joint Ore Reserves Committee (JORC) Australasian Code for Reporting of Exploration Results,
Mineral Resources and Ore Reserves.
Investigator notes the Competent Person Statement included in the appended Discover Co release.
Page | 3
15 July 2024
Pernatty Drilling Results - Show Sediment Hosted Copper Mineralisation
Discover Co Pty Ltd advises the that preliminary results from wide spaced Reverse Circulation (RC) drilling at
Pernatty, Stuart Shelf, South Australia define continuous sedimentary hosted copper mineralisation. The RC
drilling programme totalled 56 holes for 4,417 metres and was drilled in late May, 2024.
Results confirm Zambian Copper Belt (ZCB) style sediment hosted copper under shallow cover on the Stuart
Shelf, within the Gawler Craton.
Stand out results include:
o
Intersections up to 8m @ 1.06% Cu from 62m (PE046), this intersection occurs where the
targeted Tapley Hill shale thins, confirming the exploration model. The 4m interval from 58 62 m remains to be assayed.
o
Stratabound mineralisation with intersections >0.3% Cu intersected across more than 2km
o
High grade mineralisation open to the south-east, with potential for scale down-dip of drill
hole PE046
Discover Co Pty Ltd are expediting plans to drill test the scale of this discovery. Stratabound significant copper
intersections are presented below in Table 1.
Table 1: Significant Intersections
Hole ID
From
To
Interval
Intersection
PE046
62
70
8
8m @ 1.06% Cu from 62m
PE044
39
42
3
3m @ 0.83% Cu from 39m
PE007
74
79
5
5m @ 0.39 Cu% from 74m
PE009
80
86
6
6m @ 0.32 Cu% from 80m
PE002
69
73
4
4m @ 0.34% Cu from 69m
PE008
87
92
5
5m @ 0.27% Cu from 87m
PE032
25
27
2
2m @ 0.41% Cu from 25m
PE021
154
156
2
2m @ 0.4% Cu from 154m
PE004
68
69
1
1m @ 0.73% Cu from 68m
PE043
35
36
1
1m @ 0.62% Cu from 35m
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Holder
Gawler
Resources
Yandan Gold
Mines
Gawler
Resources
Gawler
Resources
Gawler
Resources
Gawler
Resources
Yandan Gold
Mines
Gawler
Resources
Gawler
Resources
Yandan Gold
Mines
Licence
EL 6642
EL 6507
EL 5738
EL 5738
El 5738
EL 5738
El 6507
EL 6642
EL 5738
EL 6507
PE031
45
48
3
3m @ 0.20% Cu from 45m
PE042
32
33
1
1m @ 0.45% Cu from 32m
PE016
120
121
1
1m @ 0.34% Cu from 120m
PE017
126
127
1
1m @ 0.34% Cu from 126m
PE001
84
85
1
1m @ 0.33% Cu from 84m
PE041
30
31
1
1m @ 0.30% Cu from 30m
PE011
33
34
1
1m @ 0.29% Cu from 33m
PE002
91
92
1
1m @ 0.27% Cu from 91m
PE005
128
129
1
1m @ 0.26% Cu from 128m
PEO53
64
68
4
4m @ 0.22% Cu from 64m
Notes:
•
•
•
Yandan Gold
Mines
Yandan Gold
Mines
Yandan Gold
Mines
Gawler
Resources
Gawler
Resources
Yandan Gold
Mines
Yandan Gold
Mines
Gawler
Resources
Gawler
Resources
Gawler
Resources
EL 6302
EL 6507
EL 6302
EL 6642
EL 57
38
EL 6507
EL 6507
EL 5378
EL 5378
EL 6642
Significant intersections calculated using 2,000ppm Cu cut off
A maximum of 2m of consecutive internal waste per calculated interval
Cu assays by 4 acid digest ICPMS methodology
Anomalous copper values >2,000ppm were encountered in several drillholes at the targeted contact
between Tapley Hill Formation sediments and the underlying Pandurra sandstone unit.
Terms of Earn-In
The drilling was executed by Discover Co Pty Ltd on licences held by Gawler Resources Pty Ltd (“Gawler”) (a
subsidiary of Investigator Resources Ltd) and Yandan Gold Mines Pty Ltd (“Yandan”) (a subsidiary of Gold
Road Ltd), pursuant to farm-in and joint venture terms executed by its subsidiary Pernatty Co Pty Ltd. On the
Gawler tenements (exploration licenses EL6401, EL6640, EL6641, EL6642 and EL6643) Discover Co has a right
to 51% and can earn an 80% equity interest by spending $4m over a 4-year period.
On the Yandan tenements (EL5929, EL6030, El6145, EL6302, EL6303, EL6436, EL6473, EL6474, EL6507,
El6583, EL6636, EL6636, El6686 and EL6793) Discover Co can earn a 70% equity interest by meeting
expenditure commitments of $11.5m over a 5.5-year period.
Interpretation of Results
Reviews of historical drilling data confirmed that the lithological characteristics of the Tapley Hill Formation,
combined with the documented presence of copper in the area and the thinning of the shales as they on-lap
the domed Pandurra formation (the Pernatty Upwarp) provides a similar basin margin setting to that which
hosts the Zambian Copper Belt deposits. Furthermore, the interpreted transition from the shallow water
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Woocalla Dolomite to deep basin Tapley Hill shales overlying the oxidising Pandurra Formation sandstones is
analogous to the best mineralised position in the Zambian model.
To summarise the comparison of the ZCB style with the regional and local context:
•
•
•
•
ZCB Cu deposits are hosted in reduced shale overlying an oxidised sandstone aquifer with best
grades developed at basin margins
the equivalent is Tapley Hill shale overlying Pandurra sandstone
the transition zone between shallow water carbonates on a basement high to adjacent basin shales
hosts the highest-grade Cu
the equivalent Stuart Shelf transition zone is between Woocalla Dolomite and Tapley Hill shale
Figure 1, illustrating a cross section from holes PE041 to PE046, highlights the presence of copper
mineralisation at the contact between the Upper Whyalla sandstone (purple bar coded SSS) and Tapley Hill
shale (yellow bar coded SSH), as well as lower in the sequence between the Tapley Hills shale and basement
Pandurra sandstone (coded SSS).
Notably, there is a thinning of the Woolcalla dolomite (light pink bar, coded SCD) in contact with the basement
Pandurra Formation, which corresponds with an increase in anomalous copper values at the basal contact of
the Tapley Hill shale and Pandurra sandstone. This area, where the Woolcalla dolomite thins into onlapping
Tapley Hill shales, is the Transition Zone and forms the principal drilling target zone.
The results from this round of drilling have more than re-confirmed the presence of copper mineralization at
the predicted and prospective stratigraphic position at the base of the Tapley Hill Formation shale overlying
the Pandurra sandstone.
Historic drilling to the south of PEO46, held in the SA state core library, will be re-analysed and re-interpreted
to evaluate the scale potential of the discovery and to identify alteration indicators to assess implications of
local faulting on the concentration of copper mineralization.
Drill hole locations are presented in Figure 2, with corresponding collar information in Table 2.
All drill assays are presented in table 3.
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Figure 1: Cross Section PE041 – PE046. Note vertical exaggeration on Z axis
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Figure 2: Northern Drill Locations
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Figure 3: Southern Drill Locations
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Table 2: RC Drilling Collar File
Hole ID
Easting
PE001
697247
PE002
697485
PE003
697677
PE004
697619
PE005
697305
PE006
697169
PE007
697164
PE008
696891
PE009
697062
PE010
707311
PE011
706933
PE012
706586
PE013
706407
PE014
705986
PE015
705743
PE016
718041
PE017
718327
PE018
718660
PE019
718957
PE020
719370
PE021
719698
PE022
713889
PE023
714295
PE024
714708
PE025
715081
PE026
715434
PE027
716268
PE028
716636
PE029
717078
PE030
717533
PE031
717900
PE032
713419
PE033
713714
PE034
714171
PE035
714359
PE036
713921
PE037
713547
PE038
714523
PE039
714751
PE040
714987
Northing
6499687
6499969
6499576
6499548
6499447
6499304
6500251
6500121
6500210
6490462
6490390
6490197
6490344
6490286
6489917
6494266
6494102
6493831
6493617
6493692
6493559
6492171
6492175
6492126
6492147
6492211
6492141
6492220
6492125
6492116
6492114
6487669
6487033
6488109
6487755
6488478
6489176
6487479
6487109
6486796
Dip
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
Azimuth
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Total
144
102
102
104
132
132
108
144
126
30
42
30
42
72
54
132
132
126
120
138
162
30
12
30
36
54
66
60
60
66
80
66
66
62
54
66
72
54
60
54
Tenement
EL 6640
EL 6640
EL 6640
EL 6640
EL 6640
EL 6640
EL 6640
EL 6640
EL 6640
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6302
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6302
EL 6302
EL 6302
EL 6302
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
EL 6507
PE041
PE042
PE043
PE044
PE045
PE046
PE047
PE048
PE049
PE050
PE051
PE052
PE053
PE054
PE055
PE056
715144
715354
715519
715707
715957
716129
705495
705311
705412
705374
705285
705018
704693
704416
704336
704278
6486374
6486076
6485682
6485351
6485009
6484710
6466554
6466232
6465942
6465524
6465153
6464895
6464643
6464427
6463948
6463579
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
59
68
60
78
72
84
54
66
72
78
72
96
90
90
78
78
EL 6507
EL 6507
EL 6507
EL 6507
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
EL 6642
Note: all coordinates in MGA Zone 50 GDA94 system.
Competent Person Statement
The information in this announcement that relates to Exploration Results is based on information and
supporting documentation compiled under the supervision of Mr Jim Kerr, a Competent Person, who
is a Member of The Australasian Institute of Mining and Metallurgy (AusIMM). Mr Kerr is a Principal
Consultant of RSC, a global resource development consultancy. Discover Co Pty Ltd has also contracted
RSC to provide contracting and other advisory services. The full nature of the relationship between Mr
Kerr, RSC, and Discover Co Pty Ltd, including any issue that could be perceived by investors as a conflict
of interest, has been disclosed. Mr Kerr has sufficient experience that is relevant to the style of
mineralisation and type of deposit under consideration and to the activity which he is undertaking to
qualify as a Competent Person as defined in the 2012 Edition of the ‘Australasian Code for Reporting
of Exploration Results, Mineral Resources and Ore Reserves.
Discover Co Pty Ltd
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
JORC Code, 2012 Edition – Table 1 report template
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections.)
Criteria
JORC Code explanation
Commentary
Sampling
techniques
• Nature and quality of sampling (eg cut channels, random chips, or specific
specialised industry standard measurement tools appropriate to the minerals
under investigation, such as down hole gamma sondes, or handheld XRF
instruments, etc). These examples should not be taken as limiting the broad
meaning of sampling.
• Include reference to measures taken to ensure sample representivity and the
appropriate calibration of any measurement tools or systems used.
• Aspects of the determination of mineralisation that are Material to the Public
Report.
• In cases where ‘industry standard’ work has been done this would be
relatively simple (eg ‘reverse circulation drilling was used to obtain 1 m
samples from which 3 kg was pulverised to produce a 30 g charge for fire
assay’). In other cases more explanation may be required, such as where
there is coarse gold that has inherent sampling problems. Unusual
commodities or mineralisation types (eg submarine nodules) may warrant
disclosure of detailed information.
• Drill type (eg core, reverse circulation, open-hole hammer, rotary air blast,
auger, Bangka, sonic, etc) and details (eg core diameter, triple or standard
tube, depth of diamond tails, face-sampling bit or other type, whether core is
oriented and if so, by what method, etc).
• Method of recording and assessing core and chip sample recoveries and
results assessed.
• Measures taken to maximise sample recovery and ensure representative
nature of the samples.
• Whether a relationship exists between sample recovery and grade and
• 56 Reverse Circulation (RC) holes for 4417 m are reported. All holes were
drilled within tenements held by Gawler Resources Pty Ltd and Yandan Gold
Mines Pty Ltd Pernatty Project, South Australia.
• The RC drill cuttings were collected from the drill rig cyclone in 1 m intervals,
bagged and arranged in rows on site for sampling and assaying.
• 1 m samples were split using a cone splitter mounted on the drill rig. Some
composite samples representing 4 m intervals were collected, as
appropriate, by sampling spear from the 1 m Metzke split samples.
• Samples were submitted to Intertek Genalysis Laboratories, Adelaide for
analysis.
Drilling
techniques
Drill sample
recovery
• The 56 holes were drilled with a Schramm T685 RC rig operated by Bullion
Drilling Pty Ltd. The RC drilling was conducted using a 5 ¾-inch hammer. A
booster air compressor was not required.
• The bulk RC samples were visually assessed and considered to be
representative with good recovery.
• Very few of the holes encountered water, with limited impact on sample
recovery. Shroud tolerance was managed to optimise recovery.
Discover Co
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Criteria
JORC Code explanation
Commentary
whether sample bias may have occurred due to preferential loss/gain of
fine/coarse material.
• Whether core and chip samples have been geologically and geotechnically
logged to a level of detail to support appropriate Mineral Resource
estimation, mining studies and metallurgical studies.
• Whether logging is qualitative or quantitative in nature. Core (or costean,
channel, etc) photography.
• The total length and percentage of the relevant intersections logged.
• There is no statistically significant relationship between recovery and grade.
Sub-sampling
techniques and
sample
preparation
• If core, whether cut or sawn and whether quarter, half or all core taken.
• If non-core, whether riffled, tube sampled, rotary split, etc and whether
sampled wet or dry.
• For all sample types, the nature, quality and appropriateness of the sample
preparation technique.
• Quality control procedures adopted for all sub-sampling stages to maximise
representivity of samples.
• Measures taken to ensure that the sampling is representative of the in situ
material collected, including for instance results for field duplicate/secondhalf sampling.
• Whether sample sizes are appropriate to the grain size of the material being
sampled.
• Drill composites of 4 m length were collected by scoop sampling from the
cyclone samples.
• Weights of samples submitted for assay averaged 2.5 kg and ranged
between 1.8 to 4.1 kg. Sample size is considered appropriate for the material
sampled.
• Commercial certified reference material of known copper grades and of
suitable matrix were included in the laboratory assay sequence at a rate of c.
1 per 25 samples.
• First-split duplicate samples were collected at a rate of 1 per 20 samples. A
coarse blank sample was inserted 1 in every 100 samples.
• A portable XRF unit was used to screen all 1 m RC bulk samples for
anomalous copper values. Where copper value readings exceeded 200 ppm
Cu, sampling was conducted at 1m intervals using Metzke cone split
samples.
• The Competent Person considers that the sample size is appropriate to the
grain size of the material being sampled
Quality of
assay data and
laboratory
tests
• The nature, quality and appropriateness of the assaying and laboratory
procedures used and whether the technique is considered partial or total.
• For geophysical tools, spectrometers, handheld XRF instruments, etc, the
parameters used in determining the analysis including instrument make and
• All samples were submitted to Intertek Genalysis Laboratories, Adelaide (ITS)
where they were oven dried and then pulverised to P80 -75 microns
(method SP03).
• Assaying of samples was conducted by ITS using a 4-acid, mass spectrometry
Logging
• All holes were qualitatively geologically logged by suitably qualified
geologists.
• Mineral Resources have not been estimated; however, the quality of the
logging is expected to be suitable for low-confidence resource estimation
purposes.
• The detail of geological logging is considered sufficient for exploration and
resource definition drilling.
• All intersections were logged.
Discover Co
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Criteria
JORC Code explanation
Commentary
model, reading times, calibrations factors applied and their derivation, etc.
• Nature of quality control procedures adopted (eg standards, blanks,
duplicates, external laboratory checks) and whether acceptable levels of
accuracy (ie lack of bias) and precision have been established.
method (code 4A/MS) for 48 elements.
• Gold was not included in the analytical suite.
• ITS internal reference materials and DiscoverCo certified reference materials
were constantly assessed for the presence of special-cause variation and the
Competent Person considers the data to show the laboratory was delivering
consistent results.
• pXRF readings were calibrated using certified reference material and blank
material.
Verification of
sampling and
assaying
• The verification of significant intersections by either independent or
alternative company personnel.
• The use of twinned holes.
• Documentation of primary data, data entry procedures, data verification,
data storage (physical and electronic) protocols.
• Discuss any adjustment to assay data.
• No twinned holes were drilled.
• The assay results are compatible with observed mineralogy.
• Primary data are stored and documented in industry standard ways
considered appropriate by the Competent Person.
• Assay data are as reported by ITS and the Competent Person has verified
these data and confirms that the data have not been adjusted in any way.
• Remnant assay pulps are stored by ITS until authorised for disposal.
Location of
data points
• Accuracy and quality of surveys used to locate drill holes (collar and downhole surveys), trenches, mine workings and other locations used in Mineral
Resource estimation.
• Specification of the grid system used.
• Quality and adequacy of topographic control.
• Drill hole locations were determined by handheld GPS with a nominal
accuracy of +/- 5 metres.
• All coordinates and maps presented here are in the MGA Zone 50 GDA94
system.
• Topographic control is provided by Worldwide 3 arc second SRTM spot
height data.
• The Competent Person considers that topographic control is of good quality.
Data spacing
and
distribution
• Data spacing for reporting of Exploration Results.
• Whether the data spacing and distribution is sufficient to establish the
degree of geological and grade continuity appropriate for the Mineral
Resource and Ore Reserve estimation procedure(s) and classifications
applied.
• Whether sample compositing has been applied.
• The reported drilling was conducted as a reconnaissance program, with
holes spaced nominally 400 m apart along pre-cleared lines constructed over
heritage cleared traverses over modelled target zones.
• Holes were completed to sufficient quality to potentially be used in any
future resource estimation, but not spatially distributed to inform a resource
estimation at this stage.
Discover Co
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Criteria
JORC Code explanation
Commentary
Orientation of
data in relation
to geological
structure
• Whether the orientation of sampling achieves unbiased sampling of possible
structures and the extent to which this is known, considering the deposit
type.
• If the relationship between the drilling orientation and the orientation of key
mineralised structures is considered to have introduced a sampling bias, this
should be assessed and reported if material.
• The measures taken to ensure sample security.
• The RC holes were drilled vertically along heritage cleared tracks or adjacent
to heritage cleared pastoral tracks.
• Geological units within the target areas are interpreted as generally flat
lying, with downhole thicknesses reported approximating true thickness.
• The results of any audits or reviews of sampling techniques and data.
• Other than the work reported here, no third-party audits or reviews of
sampling techniques and data have taken place.
Sample security
Audits or
reviews
• The chain of custody for all Pernatty samples from collection to dispatch to
assay laboratory was managed by Discover Co (DISC) personnel.
• Sample numbers are unique and do not include any locational or interval
information useful to non-Discover Co personnel. The Competent Person
considers that the level of security is appropriate for exploration drilling.
Section 2 Reporting of Exploration Results
(Criteria listed in the preceding section also apply to this section.)
Criteria
JORC Code explanation
Commentary
Mineral
tenement and
land tenure
status
• Type, reference name/number, location and ownership including agreements
or material issues with third parties such as joint ventures, partnerships,
overriding royalties, native title interests, historical sites, wilderness or
national park and environmental settings.
• The security of the tenure held at the time of reporting along with any known
impediments to obtaining a licence to operate in the area.
• Drilling was conducted within granted Exploration Licences EL 6640 and EL
6642 – held by Gawler Resources Ltd, a wholly owned subsidiary of
Investigator Resources Ltd and on granted Exploration Licences EL 6302 and
EL 6507 held by Yandan Gold Mines Pty Ltd (“Yandan”), a wholly owned
subsidiary of DGO Gold Ltd (“DGO”), which in turn is a wholly owned
subsidiary of Gold Road Ltd (“Gold Road’).
• Gawler Resources Ltd is a wholly owned subsidiary of Investigator Resources
Ltd.
• Yandan Gold Mines Pty Ltd, a wholly owned subsidiary of DGO Gold Ltd
(DGO). Yandan has agreed to sell its interest in these tenements to Discover
Co Pty Ltd (DISC). DISC are the project managers.
• Tenements are covered under a registered NTMA between the Kokatha
Discover Co
ABN 92 662 007 061
L2, 161 Collins St, Melbourne VIC 3000
Criteria
JORC Code explanation
Commentary
Aboriginal Corporation RNTB and Gawler Resources Ltd
• The licences are located within the Oakden Hills and Yudnapinna pastoral
stations.
Exploration
done by other
parties
• Acknowledgment and appraisal of exploration by other parties.
• Exploration by other parties has been reviewed and is used as a guide to
DGO’s exploration activities. Previous parties have completed drilling and
geophysical data collection and interpretation. This report makes no
reference to historical drilling results.
Geology
• Deposit type, geological setting and style of mineralisation.
• The tenements are prospective for sediment-hosted copper and cobalt
mineralisation based on a Zambian Copper Belt exploration model.
Drill hole
Information
• A summary of all information material to the understanding of the
exploration results including a tabulation of the following information for all
Material drill holes:
o easting and northing of the drill hole collar
o elevation or RL (Reduced Level – elevation above sea level in metres) of
the drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
o hole length.
• If the exclusion of this information is justified on the basis that the
information is not Material and this exclusion does not detract from the
understanding of the report, the Competent Person should clearly explain
why this is the case.
• All drill holes, including holes with no significant copper intersections, are
reported in this announcement.
• Easting and Northing are in MGA94 Zone 53
• Relative Level (RL) is Australian Height Datum (AHD).
• Dip is the inclination of the hole from the horizontal (i.e. a vertically drilled
hole from the surface is -90°). Azimuth is reported in magnetic degrees as
the direction toward which the hole is drilled (not applicable in vertical
holes).
• Down-hole length of the hole is the distance from the surface to the end of
the hole, as measured along the drill trace. Interception depth is the
distance down the hole as measured along the drill trace. Intersection width
is the downhole distance of an intersection as measured along the drill trace.
• Hole length is the distance from the surface to the end of the hole, as
measured along the drill trace.
• No results have been exclude
Share your feedback
Discover